Found 5 images also using this tag.

Sound alarm control unit

This simple unit controls three sound signals; beep, siren and buzzer. Each sound signal will only be given once when a new alarm is triggered, the input must remain clear for at least four seconds for that signal to rearm. A beep is given every six minutes if an alarm is active, as a reminder. The sound LED flashes when a sound alarm is active; once for signal 1 (beep), twice for signal 2 (siren) and three times for signal 3 (buzzer), this flashing pattern is repeated.

Read more...

Power supply and fuse monitoring module

This was the first AVR microcontroller module I ever built, it was made for and installed in the rack box project. As the name suggests it monitored that the essentials were OK, that means power supplies, fuses and communication. It used optocouplers to detect if the 5 or 12 V power supply failed, but depended on other modules for the fuse, emergency supply and communication failure.

Read more...

Module heartbeat monitor with 6 inputs

When my rack box project started filling up with modules, I needed (or rather wanted) a way of monitoring that they were running and doing what they were suppose to. I tried monitoring the fuses (1) (2), but that just wasn’t practical. I needed a way to know that the modules were not only powered, but running. This module does just that.

Read more...

Intruder alarm system controller

I build this intruder alarm controller for my old apartment. It had two modes; away and armed. It was activated either with a key switch, or using the Security keypad with programmable PIN module. When the key switch was turned, a green and red LED started to toggle back and forth. If the key was turned back on green, the away mode would activate, if on red then the system would arm. The key switch and LEDs was mounted in status panel that I had in the apartment.

Read more...

Alarm disabling unit for production equipment

This module was built for a production equipment at my previous workplace, it made it possible for an operator to silence an alarm without resolving it. Fixing an error could take some time and having the alarm horn sound during that period was very annoying, so many operators removed the alarm relay. This was unfortunate because it was not always put back, so the next alarm situation could go unnoticed. This module would silence the alarm, but still reactive it once the situation had been resolved. Eliminating the need to remove the alarm relay. Powered by: 9-24V.

Read more...

Production line stop alarm

This module was built for a production line at my previous workplace, its purpose was to serve as a single alarm system controller for an entire production line. It monitored up to eight machines, each with its own alarm timer. If an alarm was triggered; a one second signal was given with the horn. That input would then be muted, and not give any more alarm until the current alarm situation had been cleared for a minimum of seven seconds.

Read more...

Module heartbeat monitor with 15 inputs and LCD

As I started putting more and more modules into my rack box project, the previous monitoring module quickly ran out of inputs. I needed to build something bigger and better. I realized that using LEDs to show module status just wasn’t practical as the number of inputs increased. So this unit shows the module statuses on an LCD display instead, and has 15 inputs.

Read more...

Alarm disabling unit for production equipment with long stop warning

This module was built for a production equipment at my previous workplace, it made it possible for an operator to silence an alarm without resolving it. Fixing an error could take some time and having the alarm horn sound during that period was very annoying, so many operators removed the alarm relay. This was unfortunate because it was not always put back, so the next alarm situation could go unnoticed. This module would silence the alarm, but still reactive it once the situation had been resolved. Eliminating the need to remove the alarm relay. This production equipment was a temperature tester, keeping it running was vital for the temperature to be stable. Powered by: 9-24V.

Read more...